Template IPSRadiologyResultObservationComponent
IPS Radiology Result Observation ComponentThe component carries additional detailed radiological results. Depending on it's type the code and value have different constraints to reflect proper results.Type of resultConstraints for code (Value
Set)Value Domain value typeObservation TextIPS Results Radiology Textual Observations StringObservation CodeIPS Results Radiology ObservationCodeObservation Measurement, including linear, area and
volume quantity measurementsIPS Results Radiology Measurement ObservationQuantityObservation Measurement, including linear, area and volume range measurementsIPS Results Radiology Measurement ObservationInterval of quantityObservation Measurement,
including linear, area and volume ratio measurementsIPS Results Radiology Measurement ObservationRatio of quantityObservation Measurement, including linear, area and volume sampled data measurementsIPS Results Radiology Measurement ObservationSample Data
(Binary)
Actual version
Id | 2.16.840.1.113883.10.22.17 | Effective Date | 2024‑08‑04 20:18:47 |
---|
Status | Draft | Version Label | STU2 |
---|
Name | IPSRadiologyResultObservationComponent | Display Name | IPS Radiology Result Observation Component |
---|
Description | IPS Radiology Result Observation Component The component carries additional detailed radiological results. Depending on it's type the code and value have different constraints to reflect proper results. Type of result | Constraints for code (Value Set) | Value Domain value type | Observation Text | IPS Results Radiology Textual Observations | String | Observation Code | IPS Results Radiology Observation | Code | Observation Measurement, including linear, area and
volume quantity measurements | IPS Results Radiology Measurement Observation | Quantity | Observation Measurement, including linear, area and volume range measurements | IPS Results Radiology Measurement Observation | Interval of quantity | Observation Measurement,
including linear, area and volume ratio measurements | IPS Results Radiology Measurement Observation | Ratio of quantity | Observation Measurement, including linear, area and volume sampled data measurements | IPS Results Radiology Measurement Observation | Sample Data
(Binary) |
|
|
Context | Parent nodes of template element with id 2.16.840.1.113883.10.22.17 |
---|
Classification | CDA Entry Level Template |
---|
Open/Closed | Open (other than defined elements are allowed) |
---|
Relationship | Specialization: template 2.16.840.1.113883.10.12.303 CDA Observation (2005‑09‑07) ref ad1bbr- |
---|
Item | DT | Card | Conf | Description | Label |
---|
| | | | | (IPS...ent) | | @classCode
|
| cs | 1 … 1 | F | OBS | | @moodCode
|
| cs | 1 … 1 | R | | | CONF | The value of @moodCode shall be drawn from value set 2.16.840.1.113883.1.11.18943 x_ActMoodDocumentObservation (DYNAMIC) |
| | hl7:templateId
|
| II | 1 … 1 | R | | (IPS...ent) | | | @root
|
| uid | 1 … 1 | F | 2.16.840.1.113883.10.12.303 | | hl7:id
|
| II | 0 … * | | | (IPS...ent) | Choice | 1 … 1 | | Elements to choose from:- hl7:code
- hl7:code[concat(@code, @codeSystem) = doc('include/voc-2.16.840.1.113883.11.22.66-DYNAMIC.xml')//valueSet[1]/conceptList/concept/concat(@code, @codeSystem) or @nullFlavor]
- hl7:code[concat(@code, @codeSystem) = doc('include/voc-2.16.840.1.113883.11.22.80-DYNAMIC.xml')//valueSet[1]/conceptList/concept/concat(@code, @codeSystem) or @nullFlavor]
| | | hl7:code
|
| CE | 0 … 1 | R | | (IPS...ent) | | CONF | The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.40 IPS Results Radiology Observation (DYNAMIC) |
| | | hl7:code
|
| CE | 0 … 1 | R | | (IPS...ent) | | CONF | The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.66 IPS Results Radiology Textual Observations (DYNAMIC) |
| | | hl7:code
|
| CE | 0 … 1 | R | Codes identifying numeric measurements | (IPS...ent) | | CONF | The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.80 IPS Results Radiology Measurement Observation (DYNAMIC) |
| | hl7:text
|
| ED | 0 … 1 | | | (IPS...ent) | | hl7:statusCode
|
| CS | 0 … 1 | | | (IPS...ent) | | CONF | The value of @code shall be drawn from value set 2.16.840.1.113883.1.11.15933 ActStatus (DYNAMIC) |
| | hl7:effectiveTime
|
| IVL_TS | 0 … 1 | | | (IPS...ent) | Choice | 1 … 1 | | Elements to choose from:- hl7:value[@xsi:type='ST']
- hl7:value[@xsi:type='CE.IPS']
- hl7:value[@xsi:type='PQ']
- hl7:value[@xsi:type='IVL_PQ']
- hl7:value[@xsi:type='RTO_QTY_QTY']
- hl7:value[@xsi:type='BIN']
| | | hl7:value
|
| ST | 0 … 1 | R | Observation Text | (IPS...ent) | where [@xsi:type='ST'] | | | | hl7:value
|
| CE.IPS | 0 … 1 | R | Observation Code | (IPS...ent) | where [@xsi:type='CE.IPS'] | | | | hl7:value
|
| PQ | 0 … 1 | R | Observation Measurement, including linear, area and volume quantity measurements | (IPS...ent) | where [@xsi:type='PQ'] | | | Constraint | If Observation/value is a physical quantity (xsi:type="PQ"), the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC | | | hl7:value
|
| IVL_PQ | 0 … 1 | R | Observation Measurement, including linear, area and volume range measurements | (IPS...ent) | where [@xsi:type='IVL_PQ'] | | | Constraint | If Observation/value is a physical quantity, the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC | | | hl7:value
|
| RTO_QTY_QTY | 0 … 1 | R | Observation Measurement, including linear, area and volume ratio measurements | (IPS...ent) | where [@xsi:type='RTO_QTY_QTY'] | | | Constraint | If Observation/value is a physical quantity, the unit of measure SHALL be selected from ValueSet UnitsOfMeasureCaseSensitive 2.16.840.1.113883.1.11.12839 DYNAMIC | | | hl7:value
|
| BIN | 0 … 1 | R | Observation Measurement, including linear, area and volume sampled data measurements | (IPS...ent) | where [@xsi:type='BIN'] | |
|
List of all versions of this template