Template IPSMedicalDevice
Description
Keine Beschreibung in Deutsch (de-DE) verfügbar
en-US: The medical devices entry content module describes the kind of device that is, or has been used by the patient
Actual version
Id | 2.16.840.1.113883.10.22.4.26 | Effective Date | 2017‑04‑11 |
---|
Status | Under pre-publication review | Version Label | STU1 |
---|
Name | IPSMedicalDevice | Display Name | IPS Medical Device |
---|
Description | The medical devices entry content module describes the kind of device that is, or has been used by the patient |
---|
Context | Parent nodes of template element with id 2.16.840.1.113883.10.22.4.26 |
---|
Classification | CDA Entry Level Template |
---|
Open/Closed | Open (other than defined elements are allowed) |
---|
Associated with | Associated with 6 concepts | Id | Name | Data Set |
---|
hl7ips-dataelement-150 | Use end date | CEN/TC 251 prEN 17269 | hl7ips-dataelement-218 | Device content Status | CEN/TC 251 prEN 17269 | hl7ips-dataelement-57 | Device | CEN/TC 251 prEN 17269 | hl7ips-dataelement-58 | Device Type | CEN/TC 251 prEN 17269 | hl7ips-dataelement-59 | Use start date | CEN/TC 251 prEN 17269 | hl7ips-dataelement-60 | Device Identifier | CEN/TC 251 prEN 17269 |
|
|
---|
Relationship | Adaptation: template 1.3.6.1.4.1.12559.11.10.1.3.1.3.5 Medical Devices (2013‑12‑20) ref epsos- |
---|
Example | Example | <supply moodCode="EVN" classCode="SPLY"> <templateId root="2.16.840.1.113883.10.22.4.26"/> <id root="2.16.840.1.113883.19.811.3"/> <text> <reference value="#dev_1"/> </text> <effectiveTime xsi:type="IVL_TS"> <low value="20070728"/> </effectiveTime> <participant typeCode="DEV"> <participantRole classCode="MANU"> <id/> <playingDevice classCode="DEV" determinerCode="INSTANCE"> <code code="304184000" displayName="Ankle joint implant" codeSystem="2.16.840.1.113883.6.96"/> </playingDevice> </participantRole> </participant></supply> |
|
---|
Item | DT | Card | Conf | Description | Label |
---|
| | | R | The <supply> element shall be present. The moodCode attribute shall be EVN to reflect that a medical device has been provided.</supply> | (IPS...ice) | | @classCode
|
| cs | 1 … 1 | F | SPLY | | @moodCode
|
| cs | 1 … 1 | F | EVN | | hl7:templateId
|
| II | 1 … 1 | M | | (IPS...ice) | | | @root
|
| uid | 1 … 1 | F | 2.16.840.1.113883.10.22.4.26 | | hl7:id
|
| II | 0 … * | R | This optional element identifies the provision of the device (e.g. implant procedure) | (IPS...ice) | | hl7:text
|
| ED | 0 … 1 | R | | (IPS...ice) | | | hl7:reference
|
| TEL | 1 … 1 | M | | (IPS...ice) | | url | 1 … 1 | R | Reference pointing to the narrative, typically #{label}-{generated-id}, e.g. #xxx-1 | | hl7:effectiveTime
|
| IVL_TS | 1 … 1 | R |
This element provides the interval of time corresponding to the device usage by/presence in the patient.
| (IPS...ice) | | | @xsi:type
|
| st | 1 … 1 | F | IVL_TS | | | hl7:low
|
| TS | 1 … 1 | R | The lower bound of the interval represents the start date/time. | (IPS...ice) | | | hl7ips-dataelement-59 | Use start date | CEN/TC 251 prEN 17269 |
| | | hl7:high
|
| TS | 0 … 1 | C | The upper bound represents the end date/time. If it is not present, the device is still used by or present in the patient. | (IPS...ice) | | | hl7ips-dataelement-150 | Use end date | CEN/TC 251 prEN 17269 |
| | hl7:participant
|
| | 1 … * | R | The device is represented as a participant in the supply structure. The following descriptions apply to the device structure. | (IPS...ice) | | | hl7ips-dataelement-57 | Device | CEN/TC 251 prEN 17269 |
| | | @typeCode
|
| cs | 1 … 1 | F | DEV | | Example | <participant typeCode="DEV"> <participantRole classCode="MANU"> <id root="1.2.3.999" extension="__example_only__"/> <playingDevice classCode="DEV" determinerCode="INSTANCE"> <code code="" codeSystem=""/> <!-- ... --> </playingDevice> </participantRole></participant> | | Example | Presence of implanted device not known (situation) <participant typeCode="DEV"> <participantRole classCode="MANU"> <playingDevice> <code code="000000" codeSystem="2.16.840.1.113883.6.96" displayName="Presence of implanted device not known (situation)"/> </playingDevice> <scopingEntity> <id root="2.16.840.1.113883.3.3719"/> </scopingEntity> </participantRole></participant> | | Example | No implant in situ (situation) <participant typeCode="DEV"> <participantRole classCode="MANU"> <playingDevice> <code code="000000" codeSystem="2.16.840.1.113883.6.96" displayName="No implant in situ (situation)"/> </playingDevice> <scopingEntity> <id root="2.16.840.1.113883.3.3719"/> </scopingEntity> </participantRole></participant> | | | hl7:participantRole
|
| | 1 … 1 | R | | (IPS...ice) | | cs | 1 … 1 | F | MANU | | II | 0 … * | R |
The device ID, e.g. using UDI, is represented by the id element of the participant role. This element is optional, as not all production identifiers (e.g., serial number, lot/batch number, distinct identification number) may be known to the provider or patient.
| (IPS...ice) | | | hl7ips-dataelement-60 | Device Identifier | CEN/TC 251 prEN 17269 |
| | Example | UDI GS1: DeviceIdentifier 00844588003288, Serial# 10987654d321, Lot# 7654321D <id root="2.16.840.1.113883.3.3719" extension="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/> | | Example | UDI ICCBBA: DeviceIdentifier 00844588003288 <id root="2.16.840.1.113883.3.3719" extension="A9999XYZ100T0474"/> | | Example | UDI HIBCC: Serial# XYZ456789012345678, Lot# LOT123456789012345 <id root="2.16.840.1.113883.3.3719" extension="+H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C"/> | | | 1 … 1 | R | The playingDevice element describes the device instance. | (IPS...ice) | | cs | 1 … 1 | F | DEV | | cs | 1 … 1 | F | INSTANCE | | CE.IPS (preferred) | 1 … 1 | R | The device code describes the type of device (e.g. arm prosthesis, arterial stent). | (IPS...ice) | | | hl7ips-dataelement-218 | Device content Status | CEN/TC 251 prEN 17269 | hl7ips-dataelement-58 | Device Type | CEN/TC 251 prEN 17269 |
| | CONF | The value of @code comes preferably from value set 2.16.840.1.113883.11.22.23 IPS Medical Devices (DYNAMIC) | or | The value of @code comes preferably from value set 2.16.840.1.113883.11.22.61 Absent or Unknown Devices (DYNAMIC) |
|
|