Difference between revisions of "IPS implementationguide 1"
(→Introduction) |
(→Introduction) |
||
Line 22: | Line 22: | ||
__TOC__ | __TOC__ | ||
=Introduction= | =Introduction= | ||
− | {{Responsible|Philip}} | + | {{Responsible|Philip Scott}} |
− | |||
==Purpose== | ==Purpose== | ||
The goal of this Implementation Guide is to identify the required clinical data with associated vocabulary bindings and value sets for patient summary, in the context of specific use cases, and to build an international document and associated templates based on HL7 CDA R2 (or a future CDA release) and potentially the FHIR standards, with value sets to support data elements within those templates. The initial use cases will be the patient summary, providing support for emergency care and unplanned care. | The goal of this Implementation Guide is to identify the required clinical data with associated vocabulary bindings and value sets for patient summary, in the context of specific use cases, and to build an international document and associated templates based on HL7 CDA R2 (or a future CDA release) and potentially the FHIR standards, with value sets to support data elements within those templates. The initial use cases will be the patient summary, providing support for emergency care and unplanned care. |
Revision as of 15:55, 19 April 2017
This document contains: Implementation Guide International Patient Summary (0.10). The text materials belong to category cdaips.
based on Clinical Document Architecture Release 2
© 2016-2017 Health Level Seven International ® ALL RIGHTS RESERVED.
The reproduction of this material in any form is strictly forbidden without the written permission of the publisher. HL7 and Health Level Seven are registered trademarks of Health Level Seven International. Reg. U.S. Pat & TM Off.
HL7 licenses its standards and select IP free of charge. If you did not acquire a free license from HL7 for this document, you are not authorized to access or make any use of it. To obtain a free license, please visit http://www.HL7.org/implement/standards/index.cfm.
If you are the individual that obtained the license for this HL7 Standard, specification or other freely licensed work (in each and every instance "Specified Material"), the following describes the permitted uses of the Material.
A. HL7 INDIVIDUAL, STUDENT AND HEALTH PROFESSIONAL MEMBERS, who register and agree to the terms of HL7’s license, are authorized, without additional charge, to read, and to use Specified Material to develop and sell products and services that implement, but do not directly incorporate, the Specified Material in whole or in part without paying license fees to HL7.
INDIVIDUAL, STUDENT AND HEALTH PROFESSIONAL MEMBERS wishing to incorporate additional items of Special Material in whole or part, into products and services, or to enjoy additional authorizations granted to HL7 ORGANIZATIONAL MEMBERS as noted below, must become ORGANIZATIONAL MEMBERS of HL7.
B. HL7 ORGANIZATION MEMBERS, who register and agree to the terms of HL7's License, are authorized, without additional charge, on a perpetual (except as provided for in the full license terms governing the Material), non-exclusive and worldwide basis, the right to (a) download, copy (for internal purposes only) and share this Material with your employees and consultants for study purposes, and (b) utilize the Material for the purpose of developing, making, having made, using, marketing, importing, offering to sell or license, and selling or licensing, and to otherwise distribute, Compliant Products, in all cases subject to the conditions set forth in this Agreement and any relevant patent and other intellectual property rights of third parties (which may include members of HL7). No other license, sublicense, or other rights of any kind are granted under this Agreement.
C. NON-MEMBERS, who register and agree to the terms of HL7’s IP policy for Specified Material, are authorized, without additional charge, to read and use the Specified Material for evaluating whether to implement, or in implementing, the Specified Material, and to use Specified Material to develop and sell products and services that implement, but do not directly incorporate, the Specified Material in whole or in part. NON-MEMBERS wishing to incorporate additional items of Specified Material in whole or part, into products and services, or to enjoy the additional authorizations granted to HL7 ORGANIZATIONAL MEMBERS, as noted above, must become ORGANIZATIONAL MEMBERS of HL7. Please see http://www.HL7.org/legal/ippolicy.cfm for the full license terms governing the Material.
Ownership. Licensee agrees and acknowledges that HL7 owns all right, title, and interest, in and to the Materials. Licensee shall take no action contrary to, or inconsistent with, the foregoing.
Licensee agrees and acknowledges that HL7 may not own all right, title, and interest, in and to the Materials and that the Materials may contain and/or reference intellectual property owned by third parties (“Third Party IP”). Acceptance of these License Terms does not grant Licensee any rights with respect to Third Party IP. Licensee alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize Third Party IP in connection with the Materials or otherwise. Any actions, claims or suits brought by a third party resulting from a breach of any Third Party IP right by the Licensee remains the Licensee’s liability.
Following is a non-exhaustive list of third-party terminologies that may require a separate license:
Terminology | Owner/Contact |
---|---|
Current Procedures Terminology (CPT) code set | American Medical Association https://www.ama-assn.org/practice-management/cpt-licensing |
SNOMED CT© | SNOMED CT® International http://www.snomed.org/snomed-ct/get-snomed-ct or info@ihtsdo.org |
Logical Observation Identifiers Names & Codes (LOINC©) | Regenstrief Institute, Inc. |
International Classification of Diseases (ICD) codes | World Health Organization (WHO) |
NUCC Health Care Provider Taxonomy code set | American Medical Association. Please see www.nucc.org. AMA licensing contact: 312-464-5022 (AMA IP services) |
Obtaining a CPT Sublicense from HL7
Contact hq@hl7.org about how to obtain a sublicense from HL7 for non-production use of CPT for (i) the development and publication of value sets, profiles, and other artifacts as part of the HL7 Implementation Guides, (ii) as part of defined VSAC value sets, and (iii) to support HL7's terminology services within the Territory.
Flow Down Clauses for CPT Sublicense from HL7
CPT content is copyrighted by the American Medical Association and CPT is a registered trademark of the AMA.
HL7, as a party to a license agreement with the AMA, is authorized to grant user a limited, non-exclusive, non-transferable, non-sublicensable license for user to use CPT content for (i) the development and publication of value sets, profiles, and other artifacts as part of the HL7 Implementation Guides, (ii) as part of defined VSAC value sets, and (iii) to support HL7's terminology services within the Territory, each of which shall be considered a non-production use. The sublicense granted hereunder shall automatically terminate upon termination of the agreement between HL7 and AMA, unless prior written consent of AMA is obtained.
The provision of updated CPT content is dependent on a continuing contractual relationship between HL7 and the AMA.
User acknowledge a separate license agreement shall be required, and shall govern any proposed use, including any distribution of CPT content for any other purposes not expressly permitted under this Agreement, and the terms of such agreement will govern such use (e.g., a separate license agreement shall govern production use and commercial purposes). AMA reserves the right to accept or reject licenses based on AMA's evaluation of the proposed use of the CPT content.
User acknowledge that User's development and commercialization of CPT-informed works developed with reference to Licensed Products may only be implemented in the Territory.
User is prohibited from making CPT content publicly available, creating derivative works (including translating), transferring, selling, leasing, licensing, or otherwise making available to any unauthorized party the CPT content, or a copy or portion of CPT content to any unauthorized party, including a subsidiary, affiliate, or other legal entity, however designated, for any purpose whatsoever except as expressly permitted under a separate agreement.
User expressly acknowledges and agrees to the extent permitted by applicable law, use of CPT content is at User's sole risk and CPT content is provided "as is" without warranty of any kind. The AMA does not directly or indirectly practice medicine or dispense medical services. Fee schedules, relative value units, conversion factors and/or related components are not assigned by the AMA, are not part of CPT, and the AMA is not recommending their use. CPT content herein does not replace the AMA's Current Procedural Terminology book or other appropriate coding authority. The coding information contained in CPT content should be used only as a guide.
U.S. Government End Users. CPT is commercial technical data, which was developed exclusively at private expense by the American Medical Association (AMA), 330 North Wabash Avenue, Chicago, Illinois 60611. This agreement does not grant the Federal Government a direct license to use CPT based on FAR 52.227- 14 (Data Rights - General) and DFARS 252.227-7015 (Technical Data - Commercial Items).
User expressly consents to the release of its name to the AMA.
Contents
- 1 Introduction
- 2 Principles and background
- 3 Conformance clause
- 4 Functional requirements and high-level use cases
- 5 Document Level Templates
- 6 Header Level Templates
- 7 Section Level Templates
- 8 Entry Level Templates
- 8.1 Allergy and Intolerance Concern
- 8.2 Allergies and Intolerances
- 8.3 ManufacturedProduct
- 8.4 Material
- 8.5 Medication Entry
- 8.6 Reaction Manifestation
- 8.7 Problem Concern Entry
- 8.8 Problem Entry
- 8.9 Result Organizer
- 8.10 Result Observation
- 8.11 Body Author
- 8.12 Immunization
- 8.13 Immunization Medication Information
- 8.14 Laboratory Result Observation
- 8.15 Radiology Result Observation
- 8.16 Pathology Result Observation
- 8.17 Procedure Entry
- 8.18 Criticality Observation
- 8.19 Certainty Observation
- 8.20 Problem Status Observation
- 9 Appendix
- 9.1 Acronyms and abbreviations
- 9.2 Glossary
- 9.3 Licenses (for the artifacts used, for the code systems, etc.)
- 9.4 Integrated examples, links to instances
- 9.5 Validation artifacts (xsd, schematrons)
- 9.6 Links to platforms, binaries, software libraries
- 9.7 Operational information (helpdesk, actual server endpoints for testing/production/validation)
- 9.8 FAQ’s
- 9.9 References / Literature
- 9.10 How to reuse this template
- 10 List of all artifacts used in this guide
- 11 Examples (in progress)
Introduction
Purpose
The goal of this Implementation Guide is to identify the required clinical data with associated vocabulary bindings and value sets for patient summary, in the context of specific use cases, and to build an international document and associated templates based on HL7 CDA R2 (or a future CDA release) and potentially the FHIR standards, with value sets to support data elements within those templates. The initial use cases will be the patient summary, providing support for emergency care and unplanned care.
These templates/profiles aim to:
- Serve for both cross-jurisdictional (through adaptation/extension for multi-language and realm scenarios, including translation) and national (through localization) patient summaries.
- Support emergency care and unplanned care in any country (home and foreign), regardless of language
- Define value sets based on international vocabularies that are usable and understandable in any country
The deliverable(s) will address the requirements of an international patient summary:
- For the exchange of structured and coded information (section headings, entries)
- For administrative data in order to support content commitment, audit/logging/provenance
The Implementation Guide will receive input from the EHR WG regarding the specification of functional requirements on patient summaries.
This includes a compilation of the required clinical data, based on results of multiple previous projects on patient summaries (including but not limited to epSOS, ONC, Trillium Bridge, eHealth Exchange), rules and recommendations for the use and maintenance of associated vocabulary bindings and value sets (in multilingual settings), and templates for the implementation of international patient summary documents.
Therefore this Implementation Guide has its primary focus on provisions for semantic interoperability.
Templates/profiles should take in consideration, where applicable, legal, organizational, security and infrastructure requirements based on experiences of pilot implementations (Trillium Bridge).
The white paper on Comparative Analysis Between HL7 C-CDA R1.1 CCD and epSoS PS v1.4 will inform the development of the harmonized template and associated value sets.
Background
In 2010 a MoU was signed between EU and US to strengthen global cooperation in eHealth/Health. As a result, the ONC S&I “Interoperability of EHR” work group was launched in US in 2013 (http://wiki.siframework.org/EU-US+eHealth+Cooperation+Initiative) and the Trillium Bridge Project (www.trilliumbridge.eu) in Europe to compare the CDA templates specified at that time in Europe (epSOS PS V1.4) and in US (MU – C-CDA CCD v1.1) for Patient Summaries (PSs) and to build a Trans-Atlantic exchange proof of concept. Both initiatives resulted identifying the need for a common template and vocabularies for the Patient Summary, in particular the following recommendation was offered and endorsed by all members of the Joint Initiative Council and by the HL7 International Council: “to advance an International Patient Summary (IPS) standard and enable people to access and share their health information for emergency or unplanned care anywhere and as needed. At minimum the IPS should include immunizations, allergies, medications, clinical problems, past operations and implants.”
Meanwhile
- A new version of the EU/US MOU Transatlantic eHealth/health IT Cooperation Roadmap entered consultation in November 2015 , ;
- (US) a Shared Nationwide interoperability roadmap was published in November 2015 ;
- The Joint Initiative Council (JIC) on SDO Global Health Informatics Standardization, initiated the standard sets project with patient summary as its pilot ;
- A maintenance process for the European Patient Summary Guidelines is in progress (expected release on Nov 2016);
- The European eHealth Digital Service Infrastructure (project for the operational deployment of the EU cross-borders services) has been launched (2016-2018)
- ART-DECOR® and the HL7 DSTU (now STU) template exchange format are being more and more used by European countries, including for the European Patient Summary templates (aka epSOS PS template). ART DECOR is also connected to the IHE
Scope
Ballot Status of the Document
This Implementation Guide is a draft.
Audience
Relationships with other projects and guides
- Connection with CEN IPS ?
- epSOS/eHDSI; C-CDA; IHE-PCC
Prerequisite Knowledge
How to read this document
Conventions
Contributions
Principles and background
IPS Principles
(here or in the introduction ? )
What is a CDA
Templated CDA
Open and Closed Templates
Template versioning
Identifiers
- (OID,...)
Terminologies
- Focus on Value Sets
How to extend Value Sets
Datatypes used in this guide
Design conventions and principles
How to use terminology (preferred binding)
Notion of "Primary Code"
Usage of translations
Principle on negations and data known absent
- Usage of negations
- The choice for negation it is not that of using negation indicator @negationInd but rely on the terminologies to do this
- To do: add a description in the introduction
- @negationInd in CDA has been superseded in V3 later by two other negation indicators: actNegationInd valueNegationInd
- Alignment with FHIR
General implementation guidance
How to populates IDs, where I can get IDs
(Note GC: information like the relevant times for a patient summary; the description of the different statueses ; autorship;..go here or somewhere else ?
Standards used
SNOMED-CT, ...
Legend
Description of formalisms used, symbols, icons, how to read ART-DECOR tables
Conformance clause
Different conformance levels (to be explored)
Functional requirements and high-level use cases
- Add a reference to the CEN prEN. (to be analyzed)
- PSS
- Add a reference to the data set included in the html package
- Include in the functional area that no assumption on transport has been made…
- PS comes from one source, and covers different cases.
- Specify, how the provenance could be managed without going into details) to be included in next versions.
- To be further discussed, in any case add a paragraph in which explain the problem and how it might be faced.
Document Level Templates
Header Level Templates
Section Level Templates
Allergies and/or Intolerances
2.16.840.1.113883.3.1937.777.13.10.5/dynamic
History of Procedures
2.16.840.1.113883.3.1937.777.13.10.19/dynamic
Medication Summary
2.16.840.1.113883.3.1937.777.13.10.3/dynamic
Immunization
2.16.840.1.113883.3.1937.777.13.10.25/dynamic
Problems
2.16.840.1.113883.3.1937.777.13.10.8/dynamic
Entry Level Templates
Allergy and Intolerance Concern
2.16.840.1.113883.3.1937.777.13.10.6/dynamic
Allergies and Intolerances
2.16.840.1.113883.3.1937.777.13.10.24/dynamic
ManufacturedProduct
2.16.840.1.113883.3.1937.777.13.10.1/dynamic
Material
2.16.840.1.113883.3.1937.777.13.10.2/dynamic
Medication Entry
2.16.840.1.113883.3.1937.777.13.10.4/dynamic
Reaction Manifestation
2.16.840.1.113883.3.1937.777.13.10.7/dynamic
Problem Concern Entry
2.16.840.1.113883.3.1937.777.13.10.9/dynamic
Problem Entry
2.16.840.1.113883.3.1937.777.13.10.10/dynamic
Result Organizer
2.16.840.1.113883.3.1937.777.13.10.11/dynamic
Result Observation
2.16.840.1.113883.3.1937.777.13.10.12/dynamic
Body Author
2.16.840.1.113883.3.1937.777.13.10.13/dynamic
Immunization
2.16.840.1.113883.3.1937.777.13.10.14/dynamic
Immunization Medication Information
2.16.840.1.113883.3.1937.777.13.10.15/dynamic
Laboratory Result Observation
2.16.840.1.113883.3.1937.777.13.10.16/dynamic
Radiology Result Observation
2.16.840.1.113883.3.1937.777.13.10.17/dynamic
Pathology Result Observation
2.16.840.1.113883.3.1937.777.13.10.18/dynamic
Procedure Entry
2.16.840.1.113883.3.1937.777.13.10.20/dynamic
Criticality Observation
2.16.840.1.113883.3.1937.777.13.10.21/dynamic
Certainty Observation
2.16.840.1.113883.3.1937.777.13.10.22/dynamic