Item | DT | Card | Conf | Description | Label |
---|
| | | R | The <supply> element shall be present. The moodCode attribute shall be EVN to reflect that a medical device has been provided. | (IPS…ice) |
| @classCode
|
| cs | 1 … 1 | F | SPLY |
| @moodCode
|
| cs | 1 … 1 | F | EVN |
| hl7:templateId
|
| II | 1 … 1 | M | | (IPS…ice) |
| | @root
|
| uid | 1 … 1 | F | 2.16.840.1.113883.10.22.4.26 |
| hl7:id
|
| II | 0 … * | R | This optional element identifies the provision of the device (e.g. implant procedure) | (IPS…ice) |
| hl7:code
|
| CD.IPS | 0 … 1 | R | This code can be used to classify the provision of the device, e.g. the kind of implant procedure. If no implant is in situ this element is omitted. | (IPS…ice) |
| Example | <code code="71861002" codeSystem="2.16.840.1.113883.6.96" displayName="Implantation (procedure)"/> |
| hl7:text
|
| ED | 0 … 1 | R | | (IPS…ice) |
| | hl7:reference
|
| TEL | 1 … 1 | M | | (IPS…ice) |
| | 1 … 1 | R | Reference pointing to the narrative, typically #{label}-{generated-id}, e.g. #xxx-1 |
| hl7:effectiveTime
|
| IVL_TS | 1 … 1 | R | The effectiveTime element denotes the date and time the device was provided to the patient. For an implanted device, that is the date and time of implantation. If this entry indicate a past use if a device, the time interval form of shall be used, with the low and high values describing when the device was used. | (IPS…ice) |
| hl7:participant
|
| | 1 … * | R | The device is represented as a participant in the supply structure. The following descriptions apply to the device structure. | (IPS…ice) |
| | @typeCode
|
| cs | 1 … 1 | F | DEV |
| Example | <participant typeCode="DEV"> <participantRole classCode="MANU"> <id root="..." extension="..."/> <playingDevice classCode="DEV" determinerCode="INSTANCE"> <code code="" codeSystem=""/> <!-- ... --> </playingDevice> </participantRole></participant> |
| Example | Presence of implanted device not known (situation) <participant typeCode="DEV"> <participantRole classCode="MANU"> <playingDevice> <code code="000000" codeSystem="2.16.840.1.113883.6.96" displayName="Presence of implanted device not known (situation)"/> </playingDevice> <scopingEntity> <id root="2.16.840.1.113883.3.3719"/> </scopingEntity> </participantRole></participant> |
| Example | No implant in situ (situation) <participant typeCode="DEV"> <participantRole classCode="MANU"> <playingDevice> <code code="000000" codeSystem="2.16.840.1.113883.6.96" displayName="No implant in situ (situation)"/> </playingDevice> <scopingEntity> <id root="2.16.840.1.113883.3.3719"/> </scopingEntity> </participantRole></participant> |
| | hl7:participantRole
|
| | 1 … 1 | R | | (IPS…ice) |
| cs | 1 … 1 | F | MANU |
| | 0 … * | R | The device ID, e.g. using UDI, is represented by the id element of the participant role. This element is optional, as not all device identifiers (serial numbers) may be known to the provider or patient. | (IPS…ice) |
| Example | UDI GS1: DeviceIdentifier 00844588003288, Serial# 10987654d321, Lot# 7654321D <id root="2.16.840.1.113883.3.3719" extension="{01}00844588003288{17}141120{10}7654321D{21}10987654d321"/> |
| Example | UDI ICCBBA: DeviceIdentifier 00844588003288 <id root="2.16.840.1.113883.3.3719" extension="A9999XYZ100T0474"/> |
| Example | UDI HIBCC: Serial# XYZ456789012345678, Lot# LOT123456789012345 <id root="2.16.840.1.113883.3.3719" extension="+H123PARTNO1234567890120/$$420020216LOT123456789012345/SXYZ456789012345678/16D20130202C"/> |
| | 1 … 1 | R | The playingDevice element describes the device instance. | (IPS…ice) |
| cs | 1 … 1 | F | DEV |
| cs | 1 … 1 | F | INSTANCE |
| CE.IPS | 1 … 1 | R | The device code describes the type of device (e.g. arm prosthesis, arterial stent). | (IPS…ice) |
| CONF | The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.23 IPS Medical Devices (DYNAMIC) |
|