<p>Specimen Collection is used when a set of laboratory or pathology observations  produced on one or more specimens need to be associated with the minimal characteristics of the specimen(s): specimen source site and type of specimen.  In addition this template enables to convey when the specimen was collected.
 +
                    In a patient summary there is no need to provide more data than these 4:
 +
                collection method, source site, type of specimen and time of collection. An occurrence of this template describes one specimen collected, used by the set of observations present in the same Result Organizer.</p>
 
==Actual version==
 
==Actual version==
 
{{:{{BASEPAGENAME}}/dynamic}}
 
{{:{{BASEPAGENAME}}/dynamic}}
  
 
==List of all versions of this template==
 
==List of all versions of this template==
* [[2.16.840.1.113883.10.22.4.30/static-2017-04-14T000000|2017-04-14 (Under pre-publication review)]]
+
*[[2.16.840.1.113883.10.22.4.30/static-2024-08-04T210307|2024-08-04 21:03:07 (Under develeopment)]]
 +
*[[2.16.840.1.113883.10.22.4.30/static-2017-04-14T000000|2017-04-14 (Under pre-publication review)]]
 +
<!--992aae5859f55fcd70e57344ad4cb93cd76df270-->

Latest revision as of 05:11, 5 August 2024

Comments on this page

Template IPSSpecimenCollection

Specimen Collection is used when a set of laboratory or pathology observations  produced on one or more specimens need to be associated with the minimal characteristics of the specimen(s): specimen source site and type of specimen. In addition this template enables to convey when the specimen was collected. In a patient summary there is no need to provide more data than these 4: collection method, source site, type of specimen and time of collection. An occurrence of this template describes one specimen collected, used by the set of observations present in the same Result Organizer.

Actual version

Id2.16.840.1.113883.10.22.4.30Effective Date2024‑08‑04 21:03:07
Other versions this id:
  • Kblank.png IPSSpecimenCollection as of 2017‑04‑14
StatusKyellow.png DraftVersion LabelSTU2
NameIPSSpecimenCollectionDisplay NameIPS Specimen Collection
Description
Specimen Collection is used when a set of laboratory or pathology observations  produced on one or more specimens need to be associated with the minimal characteristics of the specimen(s): specimen source site and type of specimen.
In addition this template enables to convey when the specimen was collected.
In a patient summary there is no need to provide more data than these 4:
  • collection method, 
  • source site, 
  • type of specimen and 
  • time of collection.
An occurrence of this template describes one specimen collected, used by the set of observations present in the same Result Organizer.
ContextParent nodes of template element with id 2.16.840.1.113883.10.22.4.30
ClassificationCDA Entry Level Template
Open/ClosedOpen (other than defined elements are allowed)
RelationshipAdaptation: template 1.3.6.1.4.1.19376.1.3.1.2 Specimen Collection (2008‑08‑08)
ref
XDLAB-

Adaptation: template 2.16.840.1.113883.10.12.301 CDA Act (2005‑09‑07)
ref
ad1bbr-
Example
Example
<procedure classCode="PROC" moodCode="EVN">
  <templateId root="2.16.840.1.113883.10.22.4.30"/>  <code code="33882-2" codeSystem="2.16.840.1.113883.6.1" displayName="Collection date of Unspecified specimen"/>  <effectiveTime>
    <low value="20170719123716"/>  </effectiveTime>
  <targetSiteCode/>  <participant typeCode="PRD">
    <participantRole classCode="SPEC">
      <id root="1.2.3.999" extension="__example only__"/>      <playingEntity classCode="ENT" determinerCode="INSTANCE">
        <code code="122555007" codeSystem="2.16.840.1.113883.6.96" displayName="Venous blood specimen (specimen)"/>      </playingEntity>
    </participantRole>
  </participant>
</procedure>
ItemDTCardConfDescriptionLabel
hl7:procedure
(IPS...ion)
Treetree.png@classCode
cs1 … 1FPROC
Treetree.png@moodCode
cs1 … 1FEVN
Treetree.pnghl7:templateId
II1 … 1M(IPS...ion)
Treeblank.pngTreetree.png@root
uid1 … 1F2.16.840.1.113883.10.22.4.30
Treetree.pnghl7:code
CD.IPS0 … 1RLOINC code representing the act of specimen collection(IPS...ion)
Treeblank.pngTreetree.png@code
CONF0 … 1F33882-2
Treeblank.pngTreetree.png@codeSystem
0 … 1F2.16.840.1.113883.6.1 (LOINC)
Treetree.pnghl7:effectiveTime
IVL_TS0 … 1RDate and time of specimen collection(IPS...ion)
Treetree.pnghl7:methodCode
CE.IPS0 … 1R(IPS...ion)
 CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.76 IPS Results Specimen Collection Method (DYNAMIC)
Treetree.pnghl7:target​Site​Code
CE.IPS0 … 1R(IPS...ion)
 CONF
The value of @code shall be drawn from value set 2.16.840.1.113883.11.22.55 IPS Body Site (DYNAMIC)
Treetree.pnghl7:participant
0 … 1ROne single participant, which is the product of the procedure (PRD), role of specimen (SPEC) played by the playingEntity, which conveys the type of specimen collected (blood, urine, tissue, ...)(IPS...ion)
Treeblank.pngTreetree.png@typeCode
cs1 … 1FPRD
Treeblank.pngTreetree.pnghl7:participantRole
1 … 1M(IPS...ion)
Treeblank.pngTreeblank.pngTreetree.png@classCode
cs0 … 1FSPEC
Treeblank.pngTreeblank.pngTreetree.pnghl7:id
II0 … 1R(IPS...ion)
Treeblank.pngTreeblank.pngTreetree.pnghl7:playingEntity
1 … 1R(IPS...ion)
Treeblank.pngTreeblank.pngTreeblank.pngTreetree.png@determiner​Code
cs0 … 1FINSTANCE
Treeblank.pngTreeblank.pngTreeblank.pngTreetree.png@classCode
cs0 … 1FENT
Treeblank.pngTreeblank.pngTreeblank.pngTreetree.pnghl7:code
CE (preferred)1 … 1M(IPS...ion)
 CONF
The value of @code comes preferably from value set 2.16.840.1.113883.11.22.56 IPS Specimen Type (DYNAMIC)